Hotech 1.25" SCA Laser Collimator - Dot |
|
|
|
|
 |
Hotech 1.25" SCA Laser Collimator - Dot
No more guess work during the final primary mirror collimation!
Item# HTSCA-1.25D
|
|
| Model |
1.25" Single Dot SCA Laser Collimator |
| Focuser Size |
1.25" |
| Laser Wavelength |
650nm |
| Laser Output Power |
Class II, < 1mW |
| Operating Voltage |
3V |
| Battery |
One 3V Lithium Battery (included), 10 yrs shelf life, 40+ Operating Hours |
| Weight |
3.4 oz. w/ battery |
| Dimension |
1.2"/30mm dia. x 5"/127mm (L) |
| Construction |
All Areo-Space Grade Anodize Aluminum Case |
| Recommend Use |
Ideal for Newtonian Style Telescope, and
SCT Style telescope requires one-time-only star collimation
|
Feature
New Crosshair Laser Collimator Model Available No
more guess work during the final primary mirror collimation! The
crosshair laser easily guides you for a precise final collimation. The
extension crosshair helps you to center the returning laser when its
center dot disapear into the laser exiting hole. The crosshair also
makes centering the dot on the primary mirror donut an easy task during
the secondary mirror collimation.
Built-in Self Centering Adapter No more loose fitting laser
collimators! Our patented Self-Centering Adapter cleverly eliminates the
slop problem by using expanding rubber rings. As the rings expand, each
ring fills the focuser slop and center positions the laser collimator
in the drawtube. The SCA mechanism accommodates most brands of focusers
allowing repeatable installation for an accurate collimation.
High Accuracy Laser Alignment We
position the laser precisely in the exact optical path and align the
pointing of the laser beam parallel to the optical axis. It is critical
to keep the laser beam centered along the optical path for an accurate
collimation, otherwise collimating with an off-axis laser beam will
introduce astigmatism into your telescope.
Includes 45º Faceplate Viewer w/ Laser Engraved Targeting Grid The
faceplate viewer helps to display the returning laser with a clear
visual reference during collimation adjustment. The faceplate allows
you to align your primary mirror from the rear of the telescope
eliminating traveling to the front of your scope repeatedly during
collimation. HOTECH understands the importance of this, so the
faceplate is a standard feature in our SCA Laser Collimator. In
addition, the faceplate pattern is beautifully laser engraved for an
excellent target view.
Fine Projecting Laser Dot Keeping
the laser dot to the finest point is the key to precision collimation.
We limit our laser beam to the finest size to operate in the correct
distance for optimal visual effect. There is no guess work involved
like other laser collimators which is difficult to center a large
projecting laser dot to the center of the faceplate. Our understanding
and experiences of the laser design permit you to have an effective and
precision laser collimator.
Precision Machined Compact Lightweight HOTECH
engineers successfully cut the unnecessary weight on the laser
collimator because we understand that additional weight on a telescope
will create imbalance and structure sagging. The lightweight design on
our SCA Laser Collimator makes you gain reliable precision collimation.
And of course, our laser collimator is CNC machined with the tightest
tolerances. So nothing has been sacrificed while you get a
stat-of-the-art laser collimation instrument.
More SCA Laser Collimator Features:
Laser Engraved 45º Targeting Faceplate
The
targeting faceplate displays the returning laser spot with a clear
visual reference during adjustment. That allows you to align your
primary mirror from the rear of the telescope and eliminates traveling
to the front of your scope repeatedly during collimation.
Collimating
without the targeting faceplate, you will not be able to adjust the
primary mirror in real time referencing the laser dot. In
other words, you often get lost on which adjustment screws you used due
to traveling back and forth for referencing the direction you have
adjusted. This results in considerable time to complete the collimation and defeats the purpose of quick and easy laser collimation.
HoTech understands the importance of this, so the faceplate is a standard feature in our laser collimator. All astronomers deserve to have it without paying any extra!
HoTech understands the importance of this, so the faceplate is a standard feature in our laser collimator. All astronomers deserve to have it without paying any extra!
In
addition, our faceplate viewer’s pattern is laser engraved to ensure a
long lasting sharp targeting grid for best visual effects. Unlike other
collimators, the target is not a sticker that will peel, or paint that
can rub or chip off. We understand that you are paying for a precision
instrument that is supposed to be well made.
Finest Projecting Laser Dot
Keeping the laser dot to the finest point is the key to precision collimation. But
when you look closely at the laser dot from brand to brand, most laser
dots appear large, not really a fine point as you imagined. This
means there is guess work involved when you try to center the dot; not
just centering the laser dot to the center of the faceplate, but also
centering the center of the dot itself. This does not make any sense when you are trying to take the advantage of the collimated laser beam's characteristic
"which has a low beam divergence, so that the beam radius does not
undergo significant changes within moderate propagation distances." In
other words, the laser beam size within the collimation distance (laser collimator to the primary mirror and back to the faceplate) should remain a constant fine point. As you know, most laser collimator brands are not really laser manufacturers. They install
an off-the-shelf laser module or pointer and align the laser in a tube
without REALLY considering the user’s application, namely the operating
distance for a laser beam size. HoTech has been designing and building laser modules and systems for over 10 years for various professional industries. We know exactly how a laser should work. We limit our laser beam to the finest size in the correct operating distance for optimal effect. Our understanding and experiences with the laser design permit you to have an effective and precision collimation.
Proprietary Crosshair Laser Collimator Available
 With
our proprietary laser crosshair, user can zero-in the laser with ease
during the final collimation on the secondary and the primary mirror. The
crosshair model still exibits a precision laser center dot, but with a
touch of four extended laser lines from the center dot. The extension
lines (crosshair) of the laser dot is the most intuitive way to guide
the laser pointing for an accurate
adjustment. During the secondary mirror collimation, a single dot laser
projecting on the approximate center of the pre-loaded donut is
difficult to identify if the laser dot is exactly on the center. The
crosshair laser can easily help user to adjust the secondary mirror to
point the laser on the exact center with the help of the crosshair line.
During the final primary mirror collimation, the returning laser dot
often hides into the laser exiting hole preventing user to identify if
the returning laser is at exact center of the hole. Again, the
crosshair will visually guide the user to center the laser dot with ease
even when the center laser dot disappears into the exiting hole. It
is a very effective and essential feature to the SCA Laser Collimator
in obtaining at even higher degree of accuracy with ease. Click here for a video tour on YouTube.
High Accuracy Laser Alignment
Our laser collimator is well centered and aligned which are critical factors for an accurate collimation. But you will be surprised that many laser collimators in the market fail in this regard. The reason is in the design and understanding of the product itself.
We considered all aspect of parameters in our design. Parameters
like the alignment mechanism, mechanical and optical structure of the
laser itself, and more are taken as part of our design. For instance, some laser collimators actually install an off-the-shelf laser pointer in the casing. It is very cost effective (for seller), but it inherits numerous problems. In
many cases, the laser pointer might not install perfectly centered in
the casing due to pointer size variations and the added alignment
mechanism. So
the laser itself is not positioned on the true alignment point and
optical axis. As the result, the laser can never be center-aligned in
the enclosure. It is possible to align the laser beam parallel to the optical path but always with an offset along the optical axis. This
means the laser beam is off no matter how you center adapt the laser
collimator to the focuser. The result of off-centered laser will
introduce astigmatism into your telescope which is similar to figure 1's scenario.
Light Weight Design and All Aluminum Body Machined with High Precision CNC
Many
laser collimator manufacturers give users the wrong impression, “big
and heavy means rugged and stable.” Instead, HoTech engineers
successfully cut the unnecessary weight on the laser collimator because
we understand that additional weight on a telescope (especially open
structure Newtonians) will create imbalance and structure sagging. In addition, the heavier the device is, the more inertia it will have during an impact from an accidental drop. In
such an accident, the inertia force can cause more damage to the
internal alignment mechanism because there is more energy required to
dissipate from the impact. Therefore, the lightweight design on our laser collimator makes you gain reliable precision collimation. And of course our laser collimator uses aero-space grade lightweight aluminum material
and CNC machined with the tightest tolerances, then sand blasted and
anodized to protect from harsh environment. Nothing has been sacrificed
while you get a long lasting state-of-the-art collimation instrument.
Long Lasting Battery Life
By
using the CR123, 3V battery as our laser power source, our laser
collimator has over 65 hours of continuous use battery life
time. The included CR123, 3V lithium battery operates well under a
typical cold night and it has a 10 years shelf life. This is a great
advantage that you don't have to worry about changing the tiny hard to
find cell batteries frequently in the dark like other collimators.
Collimation for your SCT Commercially
made SCTs all have slight optical and mechanical alignment errors. The
error typically is in the centering of the secondary mirror. As the
result, when a laser is installed and emitted from the focuser, the beam will seldom return dead center, even though star testing would indicate perfect collimation. In addition, the secondary mirror (convex shape) expands the fine laser dot to
a larger spot, and magnifies any axial error by about 5 times. The
error of deviation for a typical well collimated SCT will return laser
beam at around 0.125" to 0.250" off center. In order to compensate the
optical and mechanical alignment errors of SCT, a different collimation
approach is required in compare with Newtonain telescope. If the
procedure is followed through correctly, users can still accurately
collimate their SCT.
By default, the laser will have to be
position in the optical center of the SCT. HoTech SCA laser
collimator automatically eliminates the focuser slop without using the
thumbscrew and center position itself on optical axis. For SCT, the
primary mirror is fixed, but you can collimate by adjusting the
secondary mirror to point parallel to the optical axis.
There is
an one-time-only preperation you need to do for SCT laser collimation.
First, install the SCA laser collimator and premark the
laser position on the target grid of the collimator when your telescope
is collimated from the factory or from your star collimation. Then when
you check for collimation next time, just adapt the SCA laser collimator
on the focuser, 2" or 1.25" and see if the laser falls on
the premarked laser position. If not, adjust the alignment screws on
the secondary mirror to move the returning laser dot to the premarked
postion on the target grid. Due to the convex shape secondary mirror
surface, the mirror will expand the returning collimating laser to a
larger spot making it harder to discern the center of the return laser
spot for collimation. For best result, the single laser dot laser model
is more suitable for the SCT collimation for ease of finding the center
of the expanded spot. See the photos below.
Diffraction Grating Pattern Lens on our SCA Laser Collimator
Since
our SCA Laser Collimator is already accurate with the SCA technology,
fine laser dot, and the built-in 45 degrees faceplate, there is no need
to use the DFG pattern to align the primary mirror of a Newtonian
telescope. The purpose of using DFG pattern is to gross alignment the primary mirror. The
user aligns the primary mirror by referencing the shadow of the
secondary in the projected DFG pattern on a wall, and user counts the
DFG dots around the shadow to center in the shadow. This method cannot achieve accurate alignment because the gap between each dot can make a big alignment difference. At the final alignment stage, the user must bring the laser dot back to the laser exit (the center of the 45 degrees faceplate). Our built-in 45 degrees faceplate
allows you to align your primary mirror from the rear of the telescope
eliminating traveling to the front of your scope repeatedly during
collimation like other collimators. Therefore, there is no need to use DFG lens in conjunction with our SCA Laser Collimator.
 |
Customers Who Bought This Item Also Bought |
|
|
|
|
|
|
|
|
|